Download Mass Spectrometry of Inorganic, Coordination and by William Henderson, J. Scott McIndoe PDF

By William Henderson, J. Scott McIndoe

Cotton S. / Коттон С.
Henderson W. / Хендерсон У.
Komiya S. / Комия С.
Lawrence G.A. / Лоренц Дж.А.
Muller U. / Мюллер У.
Rehder D. / Редер Д.
Описание:
Список книг: Amouri, H. / Амури, Х. - Chirality in Transition steel Chemistry. Molecules, Supramolecular Assemblies and fabrics (Inorganic Chemistry - A Textbook sequence) / Хиральность в химии переходных металлов. Молекулы, супрамолекулярные ансамбли и материалы (Неорганическая химия: серия учебников Wiley)
Cotton S. / Коттон С. - Lanthanide and Actinide Chemistry (Inorganic Chemistry - A Textbook sequence) / Химия лантаноидов и актиноидов (Неорганическая химия: серия учебников Wiley)
Henderson W. / Хендерсон У. - Mass Spectrometry of Inorganic, Coordination and Organometallic Compounds - Tools-Techniques-Tips (Inorganic Chemistry - A Textbook sequence) / Масс-спектрометрия неорганических, координационных и металлорганических соединений (Неорганическая химия: серия учебников Wiley)
Komiya S. / Комия С. - Synthesis of Organometallic Compounds - a pragmatic consultant (Inorganic Chemistry - A Textbook sequence) / Синтез металлорганических соединений (Неорганическая химия: серия учебников Wiley)
Lawrence G.A. / Лоренц Дж.А. - creation to Coordination Chemistry (Inorganic Chemistry - A Textbook sequence) / Введение в координационную химию (Неорганическая химия: серия учебников Wiley)
Muller U. / Мюллер У. - Inorganic Structural Chemistry (Inorganic Chemistry - A Textbook sequence) / Структурная неорганическая химия (Неорганическая химия: серия учебников Wiley)
Rehder D. / Редер Д. - Bioinorganic Vanadium Chemistry (Inorganic Chemistry - A Textbook sequence) / Бионеорганическая химия ванадия (Неорганическая химия: серия учебников Wiley)

Show description

Read or Download Mass Spectrometry of Inorganic, Coordination and Organometallic Compounds: Tools - Techniques - Tips PDF

Similar applied mathematicsematics books

The Dead Sea Scrolls After Fifty Years: A Comprehensive Assessment

This quantity is the second one in a sequence released to mark the fiftieth anniversary of the invention of the 1st scrolls at Qumran. The two-volume set encompasses a finished variety of articles protecting themes which are archaeological, historic, literary, sociological, or theological in personality. because the discovery of the 1st scrolls in 1947 an huge variety of reports were released.

Extra resources for Mass Spectrometry of Inorganic, Coordination and Organometallic Compounds: Tools - Techniques - Tips

Sample text

Mass analysis in this way takes less than a tenth of a second, and the resolution obtained is comparable to that of a quadrupole. However, it is possible to scan very slowly over a small mass window (a process known as the ‘zoomscan’), and this approach allows high resolution (up to 5000) to be obtained. By increasing the time which ions of a particular mass spend in the ion trap the resolution can be considerably improved as the relative energies of ions with the same m/z become closer in value.

F. G. Johnson, J. S. McIndoe and P. R. R. Langridge-Smith, Rapid Commun. , 2000, 14, 311; P. J. Dyson, A. K. Hearley, B. F. G. Johnson, J. S. McIndoe, P. R. R. Langridge-Smith and C. Whyte, Rapid Commun. , 2001, 15, 895; C. P. G. Butcher, P. J. Dyson, B. F. G. Johnson, P. R. R. Langridge-Smith, J. S. McIndoe and C. Whyte, Rapid Commun. , 2002, 16, 1595. 10. P. J. Dyson, A. K. Hearley, B. F. G. Johnson, T. Khimyak, J. S. McIndoe and P. R. R. LangridgeSmith, Organometallics, 2001, 20, 3970. 11. A.

The desorbed ions do have a range of velocities, which has a negative effect on the attainable resolution. This problem has been largely overcome by a technique called delayed extraction, where after a short delay a pulsed electric field accelerates the ions furthest from the desorption surface least (because these ions must have the highest velocity) and those closest most. 1 Reflectron Instruments The ions leaving the ion source of a time-of-flight mass spectrometer have neither exactly the same starting times nor exactly the same kinetic energies.

Download PDF sample

Rated 4.55 of 5 – based on 40 votes